12TBB11B43 General Electric Output module GE

Brand: GE

Model number: 12TBB11B43

Colour:new                                    Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.5kg

Category: Brand:

Description

12TBB11B43 General Electric Output module

Product Dimensions:

Product Description

GE output modules are the interface between the control system and the physical equipment. They receive signals from the PLC’s central processing unit (CPU) and use them to energize or de-energize external devices. They are generally categorized into two main types:

  • Digital Output Modules: These modules provide a simple ON/OFF command to a device. They are used to control discrete loads like relays, solenoids, indicator lights, and motor starters. The output can be either a direct voltage (DC) or an alternating voltage (AC), depending on the module.
  • Analog Output Modules: These modules generate a continuously variable voltage or current signal. This is used to control devices that require a proportional input, such as variable-speed drives, control valves, or actuators. The signal’s value directly corresponds to a specific command from the PLC (e.g., a 4-20mA signal to control a valve’s position from 0% to 100%).

These modules are engineered for reliability and safety, often featuring high current ratings, short-circuit protection, and electrical isolation.

Product Parameters (General Examples)

The parameters vary significantly by module type (e.g., RX3i, VersaMax). Here are common specifications you’ll find:

  • Number of Channels: Typically ranges from 4 to 32 channels per module, providing a high density of control points.
  • Output Type (Digital):
    • Voltage: 12/24VDC, 120VAC, or 240VAC.
    • Current Rating: The maximum current per channel, ranging from 0.5A to 2.0A or more.
    • Solid-State vs. Relay: Solid-state outputs offer faster switching and longer life, while relay outputs provide electrical isolation between the module and the load.
  • Output Range (Analog):
    • Current: 0-20mA, 4-20mA.
    • Voltage: 0-5V, 0-10V, 10V.
  • Resolution (Analog): Commonly 12-bit, 16-bit, or higher, which determines the precision of the output signal.
  • Isolation: Many modules feature channel-to-channel and channel-to-backplane isolation to prevent ground loops and protect against electrical surges.
  • Overcurrent and Short-Circuit Protection: Built-in protection that automatically disables the output in case of a fault to prevent damage to the module and the device.
  • Response Time: The time it takes for the output to activate after receiving a command from the PLC.

Product Advantages

  • High Reliability and Durability: Designed to handle the electrical loads and environmental conditions of industrial settings, ensuring continuous operation.
  • Robust Diagnostics: Many modules include advanced diagnostics that can detect faults like short circuits or open circuits, simplifying maintenance and reducing downtime.
  • Safety Features: Integrated safety features such as short-circuit protection and electrical isolation protect both the module and the controlled equipment from damage.
  • Flexibility and Scalability: A wide variety of module types allows you to select the precise functionality you need for different applications and easily expand your system.
  • Seamless Integration: Designed to integrate flawlessly with GE’s PACSystems RX3i and RX7i control platforms, ensuring optimal performance and easy configuration.
  • Hot Swappable: Many modules can be replaced while the system is running, minimizing downtime for maintenance.

Precautions

To ensure safe and reliable operation, always follow these precautions:

  • Electrostatic Discharge (ESD): Handle modules with proper ESD procedures to prevent damage to sensitive electronic components.
  • Correct Wiring: Strictly adhere to the wiring diagrams in the product manual. Incorrect wiring can damage the module or connected equipment.
  • Load Compatibility: Ensure the device you are controlling (the load) is compatible with the module’s output specifications (voltage, current rating, and type, e.g., AC or DC). Do not exceed the module’s rated current.
  • Power and Grounding: Ensure the module is properly powered and grounded to minimize electrical noise and prevent ground loops.
  • Load Type: Use the appropriate module for your load (e.g., use a relay output module for inductive loads like motors and solenoids to protect the module from voltage spikes).

Product Applications

GE output modules are used in a vast range of industrial applications, including:

  • Manufacturing and Automation: Controlling motor starters, solenoids, and indicator lights on production lines and robotic cells.
  • Process Industries: Actuating control valves, pumps, and mixers in chemical, oil & gas, and food & beverage facilities.
  • Energy and Power: Controlling circuit breakers, generator synchronization, and cooling systems in power plants and substations.
  • Water and Wastewater Treatment: Operating pumps, valves, and motor-driven mixers.
  • Building Automation: Controlling HVAC systems, lighting, and security access points.

 

 

 

 

 

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

IC660BBA025  General Electric 469-P5-HI-A20-T-H  General Electric
CR104PSG92B11  General Electric Multilin PQMII-T20-C-A  General Electric
DS200UCPBG6A  General Electric SGLA36AT0400  General Electric
IC694BEM331CA  General Electric UR 8FH  General Electric
IC697CMM711  General Electric IC697PWR711  General Electric
469-P5-HI-A20-E  General Electric IC697CPX928  General Electric
TB43400AF14  General Electric IC697BEM742  General Electric
CR120B 022 02  General Electric IS200VRTDH1D  General Electric
FT-084  General Electric IC200ALG240  General Electric
UR 7HH  General Electric IC200CHS022  General Electric
IS220PAICH2A  General Electric IC200PWR001  General Electric
IS200WROBH1A  General Electric PRCZ11  General Electric
IS200STAIH2ABB  General Electric SFLA36A10250  General Electric
IC660BBD024  General Electric IC200GBI001  General Electric
IS200STAOH2AAA  General Electric IC697RCM711  General Electric
469-P5-HI-A20-T-H  General Electric IC693PWR331  General Electric
UR 7HH  General Electric IC693CPU374  General Electric
IS220PAICH2A  General Electric 55-154607G041  General Electric
IS200WROBH1A  General Electric 55-186556G0041  General Electric
IS200STAIH2ABB  General Electric UR 8FH  General Electric
IC660BBD024  General Electric KYPDACGP1  General Electric
IS200STAOH2AAA  General Electric UR 6UH  General Electric
469-P5-HI-A20-T-H  General Electric UR 6DH  General Electric
IC694ALG221  General Electric SKPA 36AT 1200  General Electric
8851-LC-MT  General Electric UR RHH  General Electric
SFLA36A10250  General Electric IC697CPX928  General Electric
CE693PWR330  General Electric IC697CMM742  General Electric
469-P5-HI-A20-T-H  General Electric IC697BEM742  General Electric
P9XPNNG  General Electric IC697RCM711  General Electric
P9XPNNG  General Electric 369-HI-R-0-0-0-0-E  General Electric