1TGE102019R1001 ABB Processor module
Product Dimensions:
Product Description
The 1TGE102019R1001 is most likely a 3-pole, non-fused switch disconnector (or its main body/mechanism) used for safely isolating electrical circuits, such as motors, machinery, or sub-panels.
-
Type: Switch Disconnector (Load Break Switch).
-
Poles: Typically 3-pole for three-phase systems.
-
Function: Provides a means of local or remote disconnection and isolation to ensure absolute safety during maintenance, repair, or inspection of downstream equipment.
-
Enclosure/Mounting: Often designed for panel mounting or use within an enclosure (which may need to be ordered separately).
-
Operation: Manual operation via a handle (rotary or similar), providing positive indication of the contact status (ON/OFF or I/O).
Product Parameters
The specific parameters depend on the current rating associated with this code, but here are the typical specifications for this type of device:
| Parameter Category | Typical Specification / Range | Notes |
| Rated Operational Current ($I_e$) | Varies widely; e.g., $16 \text{ A}$ to $125 \text{ A}$ | Key rating for continuous operation. |
| Rated Operational Voltage ($U_e$) | Up to $690 \text{ V AC}$ | Suitable for most low-voltage industrial systems. |
| Rated Impulse Withstand Voltage ($U_{imp}$) | Typically $6 \text{ kV}$ or $8 \text{ kV}$ | Measures the device’s ability to withstand voltage surges. |
| Short-Circuit Withstand Capability | High; defined by $I_{cw}$ and $I_{pk}$ | Ability to withstand short-circuit currents for a short time. |
| Poles | $3$ (Standard) or $4$ (with Neutral) | Defines the number of phases/conductors it switches. |
| Switching Category | Typically $AC-21A$ or $AC-23A$ | Defined by IEC standards based on load type (resistive vs. inductive). |
Product Advantages
-
Safety Isolation: Provides positive visible break indication, which is crucial for operator safety and compliance with safety standards (e.g., OSHA, EN 60947-3).
-
High Reliability: Designed for demanding industrial environments, offering long mechanical and electrical life.
-
Compact Design: Optimized dimensions allow for efficient use of space within control panels and electrical enclosures.
-
Arc Quenching: Features mechanisms (like arc chutes) to efficiently extinguish the electric arc generated during switching, ensuring long contact life and reliable operation.
-
Versatile Accessories: Can be easily fitted with a wide range of accessories, such as auxiliary contacts (for signaling), terminal covers, and shaft/handle extensions.
Precautions
-
Safety Protocol (LOTO): Always follow Lockout/Tagout (LOTO) procedures when using the switch disconnector for maintenance. The handle must be padlockable in the OFF position to prevent accidental re-energization.
-
Load Type: Ensure the switch’s switching category (e.g., AC-23A for motor loads) is appropriate for the type of load being disconnected. Exceeding the rated switching capacity can cause rapid device failure.
-
Cable Sizing: Use appropriately sized cables and correct terminals for the rated operational current ($I_e$) to prevent overheating and power losses.
-
Enclosure Integrity: If the switch is mounted inside an enclosure, ensure the enclosure maintains its rated ingress protection (IP rating) after installation of the operating handle.
-
Installation: Installation must be performed by qualified electricians in accordance with the manufacturer’s instructions and all applicable electrical codes.
Product Applications
Switch disconnectors like the 1TGE102019R1001 are fundamental safety components used across numerous electrical installations:
-
Main Disconnect for Machinery: Used as the primary on/off switch to isolate an entire machine or production line for maintenance.
-
Motor Isolation: Providing local isolation for individual motors, pumps, fans, or conveyors.
-
Feeder Isolation: Serving as a sectionalizing switch to isolate parts of a distribution panel or busbar system.
-
Building Services: Used in commercial buildings for isolating HVAC equipment, lighting circuits, and power distribution sub-mains.
-
Power Distribution Boards: Essential for creating safe, isolatable sections within a distribution board.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| SD834 | ABB | EI813F | ABB |
| CI810B | ABB | AM801F | ABB |
| TB810 | ABB | SD812F | ABB |
| TK811V050 | ABB | AM811F | ABB |
| TB842 | ABB | TK802F | ABB |
| TB40A | ABB | PM803F | ABB |
| AO845A | ABB | FI820F | ABB |
| AO801 | ABB | FI810F | ABB |
| DI801 | ABB | EI803F | ABB |
| DO801 | ABB | SA801F | ABB |
| DI811 | ABB | SA811F | ABB |
| AI810 | ABB | SB808F | ABB |
| AI830A | ABB | FI830F | ABB |
| DP840 | ABB | SD802F | ABB |
| AO845A | ABB | AM895F | ABB |
| AI835A | ABB | SY809F | ABB |
| DO810 | ABB | EI812F | ABB |
| TB820V2 | ABB | EI811F | ABB |
| AO810V2 | ABB | RLM01 | ABB |
| AI820 | ABB | PM902F | ABB |
| DI821 | ABB | CI930F | ABB |
| AO820 | ABB | CP430B | ABB |
| DO802 | ABB | CP430T | ABB |
| CI801 | ABB | CP450T | ABB |
| DI810 | ABB | CP450T-ETH | ABB |
| AI845 | ABB | CP620 | ABB |
| AI801 | ABB | 07KT95 | ABB |
| DI803 | ABB | 07CR41 | ABB |
| DI802 | ABB | 07DC92 | ABB |
| TB40A | ABB | 07DI92 | ABB |
| CI840A | ABB | XI16E1 | ABB |
| TB825 | ABB | 07KP53 | ABB |
| BC810K02 | ABB | 07AI91 | ABB |
| PM866K02 | ABB | 3BSE018168R1 | ABB |
| PM861AK02 | ABB | 07KT98 | ABB |
| TB852 | ABB | 1SAP520100R0001 | ABB |
| PM851AK01 | ABB | GJR5252800R0100 | ABB |




Phone:
Email:
WhatsApp: