Description
3RG4613-3AB01 SIEMENS Digital input module
Product Dimensions:
Product Description
The SIEMENS Digital Input (DI) Module is a fundamental component of industrial automation systems (like SIMATIC PLC or Distributed I/O) that provides the interface between the central controller and the field-level binary sensors and switches. Its primary function is to reliably detect and digitize the ON/OFF state of field devices.
Product Parameters
| Feature Category | Description (General) |
| Core Functionality | Reads and converts binary (ON/OFF, 1/0) electrical signals from field devices into a digital format that can be processed by the PLC’s CPU. |
| Channel Density | Available in various densities (e.g., 8, 16, 32 channels per module) to suit different space and I/O count requirements. |
| Rated Voltage | Typically available for common industrial voltage levels, most frequently 24 V DC, but also AC voltage variants. |
| Input Type | Supports different wiring principles: |
| * Sink (PNP/P-reading): Detects a positive voltage signal (common for European/PNP sensors). | |
| * Source (NPN/M-reading): Detects a connection to ground/negative potential. | |
| Input Delay Time | Configurable input delay (e.g., from 0.05 ms up to 20 ms) to filter out brief signal spikes (noise) or adapt to fast-switching signals. |
| Signal Standard | Often compliant with international standards, such as IEC 61131, Type 1 or Type 3 requirements for connecting sensors. |
| Special Functions | High-Feature (HF) or Technology modules may include integrated functions like high-speed counting or process interrupts. |
Product Advantages
- Reliable Signal Acquisition: Designed with robust circuitry and configurable filters to ensure accurate detection of binary signals even in electrically noisy industrial environments.
- High Density and Compact Design: Modular, space-saving design allows for a large number of inputs in a limited cabinet space, improving system footprint efficiency.
- Advanced Diagnostics: Includes comprehensive channel and module diagnostics, such as monitoring for wire breaks, short circuits in the sensor supply, and power supply issues, enabling fast fault identification and minimizing downtime.
- Flexibility (Configurability): Key parameters like input delay time and diagnostic responses can be configured via the engineering software (TIA Portal) to adapt the module to specific application requirements and sensor types.
- Fast Response (HF Modules): High-speed variants offer very low signal delay times and process interrupt capabilities, making them suitable for time-critical, high-precision applications.
- Hot Swapping: Many modules support hot swapping, allowing replacement without powering down the entire station, thus enhancing system availability.
Product Applications
- Machine Control: Monitoring the state of essential machine components, such as limit switches, proximity sensors, safety gate contacts, and control panel pushbuttons.
- Process Interlocking: Reading binary conditions required to start, stop, or interlock process sequences (e.g., valve position feedback).
- High-Speed Sensing: Using high-feature modules to capture signals from fast-switching sensors (e.g., photo-eyes on a conveyor) for tasks like counting or immediate sequence reaction.
- Safety Integration: Employed in safety systems (often as specialized fail-safe modules) to monitor the state of emergency stop buttons and safety-rated sensors.
- General Status Monitoring: Monitoring the ON/OFF status of motors, pumps, fans, and indicator lights in building automation and facility management systems.
Important Considerations
- Wiring Principle: Ensure the module’s input type (Sink/PNP or Source/NPN) matches the output type of the connected field device/sensor. Mixing these can damage the components.
- Sensor Power: Check the module’s technical data for maximum allowable current draw for the sensor supply to prevent overloading the integrated power distribution.
- Input Delay Setting: The input delay must be configured carefully. A delay that is too long will slow down the system’s reaction time, while one that is too short may allow electrical noise to be registered as a valid signal.
- Voltage and Isolation: Verify that the rated input voltage of the module matches the field voltage. Pay attention to channel isolation specifications, especially when connecting different voltage potentials.
- Cable Length: Adhere to the specified maximum cable lengths (shielded and unshielded) to prevent signal degradation and maintain noise immunity.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| 6GK5206-1BC10-2AA3 | SIEMENS | 6SE6400-0AP00-0AA1 | SIEMENS |
| 6ES7193-0CB20-0XA0 | SIEMENS | 6XV1840-3AH10 60m | SIEMENS |
| 6ES7323-1BH01-0AA0 | SIEMENS | QMX2.P33 | SIEMENS |
| 16137-175 | SIEMENS | PXC100-E96A | SIEMENS |
| 6GK443-1EX30-0XE1 | SIEMENS | 5SX2102-7 | SIEMENS |
| 6EP3331-6SB00-0AY0 | SIEMENS | 3ZX1012-ORTO2-1AA1 | SIEMENS |
| PXC50-E.D | SIEMENS | 6ES7151-1BA02-0AB0 | SIEMENS |
| 6AV2124-0QC24-1AX0 | SIEMENS | 6FX2001-6AA12-2AA5- 1 | SIEMENS |
| 6SL31201TE285AA3 | SIEMENS | 6ES7195-7HB00-0XA0 | SIEMENS |
| 6SL31622BM000AA0 | SIEMENS | 6SL34202TE150AA1 | SIEMENS |
| 6SE7972-0CB20-0XA0 | SIEMENS | 6SL3053-0AA00-3AA1 | SIEMENS |
| 3RX9307-1AA00 | SIEMENS | 6AV2124-0JC01-0AX0-ZA01+S00 | SIEMENS |
| 3RK1903-3AC00 | SIEMENS | QRA75.A17 | SIEMENS |
| 6GK5992-1AG00-8AA0 | SIEMENS | 3RT1054-1AT36 | SIEMENS |
| 6GK5980-3CB00-0AA1 | SIEMENS | 7MF4033-1DA10-1AC6-Z | SIEMENS |
| 6AG4141-0BA34-0EA0 | SIEMENS | 6AV8100-1CB00-0AA1 | SIEMENS |
| 5SU1324-7FA06 | SIEMENS | 3VL1705-1DA33-0AB1 | SIEMENS |
| 6SE7011-5EP50-Z | SIEMENS | 6SA8252-0BC83 | SIEMENS |
| 6DR2803-8P | SIEMENS | 6SN1124-1AB00-0HA1 | SIEMENS |
| FK-6DR4004-8J | SIEMENS | AK1703ACP | SIEMENS |
| 6SL3210 -1SE31-0UA0 | SIEMENS | 6SL3225-0BH27-5AA1 | SIEMENS |
| 6AV6645-0DE01-0AX1 | SIEMENS | 3TY7530-0A | SIEMENS |
| 6XV1870-8AN30 | SIEMENS | 3UG4512-1AR20 | SIEMENS |
| 3SE5132-0CJ82 | SIEMENS | 7SJ8021-5EB90-1FA0/DD | SIEMENS |
| 3RT1046-1BB44 + 3RH1921-1HA22 | SIEMENS | 3RH2911-1HA02 | SIEMENS |
| 3TF4522-0XM0 | SIEMENS | 6ES7288-1CR40-0AA0 | SIEMENS |
| 6AV2128-3UB06-0AX1 | SIEMENS | 6SE7090-0XX84-3EH0 | SIEMENS |
| 6SL3220-3YE30-0UF0 | SIEMENS | 6ES7135-0HF01-0XB0 | SIEMENS |
| 6SL3220-1YE34-0UF0 | SIEMENS | 6AG1134-4GB01-2AB0 | SIEMENS |
| TXM1.4D3R | SIEMENS | 6SC6508-4AA02 | SIEMENS |
| TXM1.6R | SIEMENS | 6SL3130-7TE25-5AA3 | SIEMENS |
| PXC4.E16 | SIEMENS | 8PQ9142-2AA04 | SIEMENS |
| QBM3120 | SIEMENS | 6ES7-214-1BD23-0XB8 | SIEMENS |
| TXS1-EF10 | SIEMENS | PXG80-N | SIEMENS |
| 6AG1231-4HD32-4XB0 | SIEMENS | 6GK51011BB002AA3 | SIEMENS |
| QVE1901 | SIEMENS | 6AG1137-6AA00-2BA0 | SIEMENS |
| QPA1004 | SIEMENS | 6EP1334-1AL11 | SIEMENS |
| GLB161.1E | SIEMENS | 6FX8002-2DC10-1EA0 | SIEMENS |



Phone:
Email:
WhatsApp: