Description
3RT1045-1AK60 SIEMENS Interface module
Product Dimensions:
Product Description
The Siemens Interface Module (IM) is the control centerpiece of a Distributed I/O system, primarily the SIMATIC ET 200 series. Its fundamental role is to establish and manage the high-speed data exchange between a central PLC (controller) and the remote I/O station where the module is housed. It acts as the gateway or “head station” for the decentralized I/O modules (Digital, Analog, Technology) connected to it.
The Interface Module acts as a PROFINET IO Device or PROFIBUS DP Slave.
- Communication: It terminates the industrial communication bus (e.g., PROFINET or PROFIBUS) in the distributed I/O station.
- Data Aggregation: It collects all input data from the connected I/O modules and packages it for synchronous transmission to the central PLC. Conversely, it receives output data from the PLC and distributes it to the appropriate I/O modules.
- Station Management: It provides essential functions for the remote station, including:
- Managing the backplane bus for internal communication among the I/O modules.
- Supplying power to the electronics and communication components.
- Executing local diagnostics and station monitoring.
Product Parameters
| Parameter Category | Specification Range | Significance |
| Fieldbus Protocols | PROFINET IO, PROFIBUS DP, Industrial Ethernet variants. | Defines the network compatibility and data transmission speed. |
| Max. I/O Modules | Up to 32, 64, or more I/O modules per IM. | Defines the maximum capacity and size of the remote I/O station. |
| Update Time | Down to fractions of a millisecond (e.g., $250 mutext{s}$) in Isochronous Mode. | High-speed data exchange is crucial for fast machine applications. |
| Redundancy Support | Media Redundancy Protocol (MRP), System Redundancy (S2/R1). | Ensures high availability by providing redundant communication paths or controller connections. |
| Power Supply | $24 text{V DC}$ (standard) with integrated reverse polarity protection. | Standardized power requirement for industrial environments. |
| Diagnostics | Network status, station faults, module status, topology errors. | Comprehensive local and network-level fault reporting. |
Product Advantages
- Decentralization and Reduced Wiring: Enables the placement of I/O close to the field devices, drastically reducing the required length of field wiring and simplifying cable management compared to centralized cabinets.
- High Performance: Modern IMs support high-speed real-time communication protocols (like PROFINET IRT) and Isochronous Mode, ensuring deterministic and time-synchronized data exchange for critical control tasks.
- Scalability and Flexibility: The modular concept allows users to add or remove I/O modules behind the IM without complex network changes, adapting easily to expanding machine or plant requirements.
- Integrated Diagnostics: The IM centralizes diagnostic information from all connected I/O modules and the network connection, providing simple, clear status indicators and detailed fault reporting to the PLC via the network.
- Hot Swapping (Module Replacement During Operation): Due to the active backplane bus and design, many IMs and their I/O modules can be replaced without powering down the entire station or interrupting communication to the rest of the network, maximizing machine uptime.
Important Notes
- Bus Termination: In PROFIBUS networks, ensure that the communication line is correctly terminated at both ends of the segment (typically via a switch on the IM) to prevent signal reflection and ensure reliable communication.
- Addressing: Each Interface Module must be assigned a unique PROFIBUS address or PROFINET device name in the network to ensure proper data routing by the central controller.
- GSD/GSDML Files: The IM’s device description file (GSD or GSDML) must be imported into the engineering software (e.g., TIA Portal) to correctly configure the remote station’s hardware structure and its data exchange with the PLC.
- Power Segment Limits: Be aware of the maximum current load the IM can support for the connected I/O modules. Larger stations may require separate Power Modules to establish additional power segments.
Product Applications
- Large Machine Tools and Production Lines: Used to manage I/O points spread across long transfer lines or complex machinery, minimizing installation costs and complexity.
- Conveyor Systems and Logistics: Centralizing control and diagnostics for large networks of sensors and actuators distributed over wide areas in warehouses or material handling facilities.
- Hazardous Areas (Ex Zones): Specialized Interface Modules are available to manage I/O intrinsically safe barriers in hazardous environments, allowing for safe data acquisition and control from explosion-risk zones.
- Modular Plant Design: Facilitates the creation of self-contained, pre-tested equipment modules that can be quickly and easily integrated into a main control system simply by plugging in the industrial network cable.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| 6GK5206-1BC10-2AA3 | SIEMENS | 6SE6400-0AP00-0AA1 | SIEMENS |
| 6ES7193-0CB20-0XA0 | SIEMENS | 6XV1840-3AH10 60m | SIEMENS |
| 6ES7323-1BH01-0AA0 | SIEMENS | QMX2.P33 | SIEMENS |
| 16137-175 | SIEMENS | PXC100-E96A | SIEMENS |
| 6GK443-1EX30-0XE1 | SIEMENS | 5SX2102-7 | SIEMENS |
| 6EP3331-6SB00-0AY0 | SIEMENS | 3ZX1012-ORTO2-1AA1 | SIEMENS |
| PXC50-E.D | SIEMENS | 6ES7151-1BA02-0AB0 | SIEMENS |
| 6AV2124-0QC24-1AX0 | SIEMENS | 6FX2001-6AA12-2AA5- 1 | SIEMENS |
| 6SL31201TE285AA3 | SIEMENS | 6ES7195-7HB00-0XA0 | SIEMENS |
| 6SL31622BM000AA0 | SIEMENS | 6SL34202TE150AA1 | SIEMENS |
| 6SE7972-0CB20-0XA0 | SIEMENS | 6SL3053-0AA00-3AA1 | SIEMENS |
| 3RX9307-1AA00 | SIEMENS | 6AV2124-0JC01-0AX0-ZA01+S00 | SIEMENS |
| 3RK1903-3AC00 | SIEMENS | QRA75.A17 | SIEMENS |
| 6GK5992-1AG00-8AA0 | SIEMENS | 3RT1054-1AT36 | SIEMENS |
| 6GK5980-3CB00-0AA1 | SIEMENS | 7MF4033-1DA10-1AC6-Z | SIEMENS |
| 6AG4141-0BA34-0EA0 | SIEMENS | 6AV8100-1CB00-0AA1 | SIEMENS |
| 5SU1324-7FA06 | SIEMENS | 3VL1705-1DA33-0AB1 | SIEMENS |
| 6SE7011-5EP50-Z | SIEMENS | 6SA8252-0BC83 | SIEMENS |
| 6DR2803-8P | SIEMENS | 6SN1124-1AB00-0HA1 | SIEMENS |
| FK-6DR4004-8J | SIEMENS | AK1703ACP | SIEMENS |
| 6SL3210 -1SE31-0UA0 | SIEMENS | 6SL3225-0BH27-5AA1 | SIEMENS |
| 6AV6645-0DE01-0AX1 | SIEMENS | 3TY7530-0A | SIEMENS |
| 6XV1870-8AN30 | SIEMENS | 3UG4512-1AR20 | SIEMENS |
| 3SE5132-0CJ82 | SIEMENS | 7SJ8021-5EB90-1FA0/DD | SIEMENS |
| 3RT1046-1BB44 + 3RH1921-1HA22 | SIEMENS | 3RH2911-1HA02 | SIEMENS |
| 3TF4522-0XM0 | SIEMENS | 6ES7288-1CR40-0AA0 | SIEMENS |
| 6AV2128-3UB06-0AX1 | SIEMENS | 6SE7090-0XX84-3EH0 | SIEMENS |
| 6SL3220-3YE30-0UF0 | SIEMENS | 6ES7135-0HF01-0XB0 | SIEMENS |
| 6SL3220-1YE34-0UF0 | SIEMENS | 6AG1134-4GB01-2AB0 | SIEMENS |
| TXM1.4D3R | SIEMENS | 6SC6508-4AA02 | SIEMENS |
| TXM1.6R | SIEMENS | 6SL3130-7TE25-5AA3 | SIEMENS |
| PXC4.E16 | SIEMENS | 8PQ9142-2AA04 | SIEMENS |
| QBM3120 | SIEMENS | 6ES7-214-1BD23-0XB8 | SIEMENS |
| TXS1-EF10 | SIEMENS | PXG80-N | SIEMENS |
| 6AG1231-4HD32-4XB0 | SIEMENS | 6GK51011BB002AA3 | SIEMENS |
| QVE1901 | SIEMENS | 6AG1137-6AA00-2BA0 | SIEMENS |
| QPA1004 | SIEMENS | 6EP1334-1AL11 | SIEMENS |
| GLB161.1E | SIEMENS | 6FX8002-2DC10-1EA0 | SIEMENS |



Phone:
Email:
WhatsApp: