Description
3SB3001-2KA71 SIEMENS Digital input module
Product Dimensions:
Product Description
A Siemens digital input module serves as the primary link between the physical process and the automation controller. It monitors the status of binary field devices—detecting whether a circuit is open or closed—and transmits this status to the internal image table of the PLC. These modules are engineered to handle the conversion of various voltage levels, provide electrical isolation between the field and the internal bus, and filter out mechanical contact bounce or electrical noise to ensure signal integrity.
Product Parameters
The technical specifications of these modules are tailored to meet diverse industrial requirements:
-
Input Voltage Levels: Support for standard DC voltages (commonly 24V) or AC voltages (commonly 120V/230V).
-
Number of Channels: High-density configurations ranging from 8 to 32 channels per module to optimize cabinet space.
-
Input Delay: Adjustable filter times to compensate for contact bounce or to capture high-speed pulses.
-
Isolation: Galvanic isolation between the field-side electronics and the backplane bus to protect the CPU from surges.
-
Current Consumption: Low power draw from the backplane bus to ensure energy efficiency and minimize heat.
-
Diagnostics: Integrated status indicators for each channel and advanced diagnostic capabilities to detect wire breaks or short circuits.
Product Advantages
-
High Reliability: Built with robust electronic components that ensure consistent performance even in environments with significant vibration or temperature fluctuations.
-
Simplified Engineering: Fully integrated into the TIA Portal framework, allowing for easy hardware configuration, parameter assignment, and addressing.
-
Space Efficiency: Compact design allows for high-density I/O counts, reducing the overall footprint of the control system within the electrical cabinet.
-
Flexible Scaling: Modules can be added or replaced easily, allowing the system to grow alongside the complexity of the machinery.
-
Safety Integration: Specialized versions are available for safety-related applications, ensuring compliance with international functional safety standards.
Usage Precautions
-
Polarity Accuracy: For DC modules, ensuring correct polarity of the input signal is essential to prevent damage or failure to detect the signal.
-
Signal Filtering: Appropriate input delay times must be configured to prevent the PLC from misinterpreting mechanical switch bounce as multiple signals.
-
Voltage Consistency: The voltage supplied by the field sensors must match the rated input voltage of the module to avoid hardware failure or intermittent detection.
-
Wiring Density: Careful cable management is required for high-density modules to prevent heat buildup and ensure easy access for maintenance.
-
Common Potential: Ensure that the common return path (M-terminal) is correctly connected to provide a stable reference for the input circuits.
Product Applications
-
Process Monitoring: Detecting the status of limit switches, proximity sensors, and level switches across production lines.
-
Operator Interface: Capturing manual commands from pushbuttons, selector switches, and emergency stop devices.
-
Feedback Loops: Receiving digital feedback from motor starters, valves, and actuators to verify their operational state.
-
Sequence Control: Providing the binary triggers required for step-by-step logic execution in automated assembly or packaging systems.
-
Fault Detection: Monitoring auxiliary contacts of protective devices to trigger alarms or safety shutdowns when a fault occurs.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| 6GK5206-1BC10-2AA3 | SIEMENS | 6SE6400-0AP00-0AA1 | SIEMENS |
| 6ES7193-0CB20-0XA0 | SIEMENS | 6XV1840-3AH10 60m | SIEMENS |
| 6ES7323-1BH01-0AA0 | SIEMENS | QMX2.P33 | SIEMENS |
| 16137-175 | SIEMENS | PXC100-E96A | SIEMENS |
| 6GK443-1EX30-0XE1 | SIEMENS | 5SX2102-7 | SIEMENS |
| 6EP3331-6SB00-0AY0 | SIEMENS | 3ZX1012-ORTO2-1AA1 | SIEMENS |
| PXC50-E.D | SIEMENS | 6ES7151-1BA02-0AB0 | SIEMENS |
| 6AV2124-0QC24-1AX0 | SIEMENS | 6FX2001-6AA12-2AA5- 1 | SIEMENS |
| 6SL31201TE285AA3 | SIEMENS | 6ES7195-7HB00-0XA0 | SIEMENS |
| 6SL31622BM000AA0 | SIEMENS | 6SL34202TE150AA1 | SIEMENS |
| 6SE7972-0CB20-0XA0 | SIEMENS | 6SL3053-0AA00-3AA1 | SIEMENS |
| 3RX9307-1AA00 | SIEMENS | 6AV2124-0JC01-0AX0-ZA01+S00 | SIEMENS |
| 3RK1903-3AC00 | SIEMENS | QRA75.A17 | SIEMENS |
| 6GK5992-1AG00-8AA0 | SIEMENS | 3RT1054-1AT36 | SIEMENS |
| 6GK5980-3CB00-0AA1 | SIEMENS | 7MF4033-1DA10-1AC6-Z | SIEMENS |
| 6AG4141-0BA34-0EA0 | SIEMENS | 6AV8100-1CB00-0AA1 | SIEMENS |
| 5SU1324-7FA06 | SIEMENS | 3VL1705-1DA33-0AB1 | SIEMENS |
| 6SE7011-5EP50-Z | SIEMENS | 6SA8252-0BC83 | SIEMENS |
| 6DR2803-8P | SIEMENS | 6SN1124-1AB00-0HA1 | SIEMENS |
| FK-6DR4004-8J | SIEMENS | AK1703ACP | SIEMENS |
| 6SL3210 -1SE31-0UA0 | SIEMENS | 6SL3225-0BH27-5AA1 | SIEMENS |
| 6AV6645-0DE01-0AX1 | SIEMENS | 3TY7530-0A | SIEMENS |
| 6XV1870-8AN30 | SIEMENS | 3UG4512-1AR20 | SIEMENS |
| 3SE5132-0CJ82 | SIEMENS | 7SJ8021-5EB90-1FA0/DD | SIEMENS |
| 3RT1046-1BB44 + 3RH1921-1HA22 | SIEMENS | 3RH2911-1HA02 | SIEMENS |
| 3TF4522-0XM0 | SIEMENS | 6ES7288-1CR40-0AA0 | SIEMENS |
| 6AV2128-3UB06-0AX1 | SIEMENS | 6SE7090-0XX84-3EH0 | SIEMENS |
| 6SL3220-3YE30-0UF0 | SIEMENS | 6ES7135-0HF01-0XB0 | SIEMENS |
| 6SL3220-1YE34-0UF0 | SIEMENS | 6AG1134-4GB01-2AB0 | SIEMENS |
| TXM1.4D3R | SIEMENS | 6SC6508-4AA02 | SIEMENS |
| TXM1.6R | SIEMENS | 6SL3130-7TE25-5AA3 | SIEMENS |
| PXC4.E16 | SIEMENS | 8PQ9142-2AA04 | SIEMENS |
| QBM3120 | SIEMENS | 6ES7-214-1BD23-0XB8 | SIEMENS |
| TXS1-EF10 | SIEMENS | PXG80-N | SIEMENS |
| 6AG1231-4HD32-4XB0 | SIEMENS | 6GK51011BB002AA3 | SIEMENS |
| QVE1901 | SIEMENS | 6AG1137-6AA00-2BA0 | SIEMENS |
| QPA1004 | SIEMENS | 6EP1334-1AL11 | SIEMENS |
| GLB161.1E | SIEMENS | 6FX8002-2DC10-1EA0 | SIEMENS |



Phone:
Email:
WhatsApp:

