Description
3UF5011-3AN00-1 SIEMENS Power module
Product Dimensions:
Product Description
A Siemens Power Module (often functioning as a Power Supply Unit or PS) is a critical component in a modular automation system (such as a PLC rack or remote I/O station). Its primary function is to convert the incoming raw AC or DC main voltage into the regulated, low-voltage DC power required to operate the PLC backplane, the Processor Module, and the I/O modules.
It ensures a stable and clean power supply, which is essential for the reliable functioning of all electronic components in the control system. Advanced power modules also provide integrated diagnostic features to monitor the health of the power source and communicate status information to the CPU.
Product Parameters
The specifications define the module’s electrical conversion and protective capabilities:
| Parameter | Description |
| Input Voltage Range | The range of AC or DC voltage the module can accept (e.g., $100text{-}240text{V AC}$ universal input, or $24text{V DC}$). |
| Output Voltage | The regulated DC voltage supplied to the backplane, typically $24text{V DC}$ and often $5text{V DC}$ or $3.3text{V DC}$ for internal electronics. |
| Output Power/Current | The maximum continuous power (Watts) or current (Amps) the module can deliver to the backplane (e.g., $10text{A}$ at $24text{V DC}$). |
| Efficiency | The percentage of input power converted into useful output power, typically $ge 90%$. |
| Hold-up Time | The duration (in $text{ms}$) that the output voltage remains stable above the minimum threshold after the input power is completely lost. |
| Overload Protection | Integrated features to shut down or limit current output in case of short circuits or excessive load demands. |
| Operating Temperature | The ambient temperature range over which the module can deliver its rated power without derating. |
Product Advantages
-
High Stability and Regulation: Provides tightly regulated DC power, maintaining constant voltage levels despite fluctuations in the input power or changes in the system load.
-
Integrated Diagnostics: Features status LEDs and often communication channels to report power status, overload conditions, and input voltage presence directly to the PLC’s diagnostic buffer.
-
Wide Range Input: Many modules accept a wide range of input voltages (e.g., global usage), simplifying inventory and making the system compatible with different global power grids.
-
High Efficiency: Modern designs boast high energy conversion efficiency, reducing heat dissipation within the control cabinet and lowering operational costs.
-
Redundancy Support: Advanced power modules can be operated in parallel with others to achieve redundancy (N+1) for critical applications, ensuring continuous operation upon the failure of one module.
Important Precautions
-
Correct Sizing: The power module’s output capacity (Amps/Watts) must be correctly sized to cover the total power consumption of all connected components (CPU, I/O modules, communication modules) plus a safety margin.
-
Ventilation: Due to the heat generated during power conversion, ensure adequate free space and ventilation around the module to prevent overheating and thermal derating (reduction of output capacity).
-
Grounding and Fusing: Ensure the input power is correctly fused externally and that the module’s protective earth (PE) connection is properly bonded to the control cabinet ground.
-
Input Voltage Check: Always verify that the connected input voltage source is within the specified acceptable range of the power module before powering up the system.
-
Hot Swapping: Do not attempt to remove or insert a power module into the rack unless the procedure explicitly permits hot swapping, as this could damage the backplane or the module itself.
Product Applications
Power Modules are a necessary component in virtually every Siemens modular automation setup:
-
Control Cabinets: Providing the essential, regulated DC power to the core PLC rack in manufacturing, process control, and machine automation systems.
-
Distributed I/O Stations: Supplying local power to remote I/O modules deployed near field devices, often in conjunction with an Interface Module.
-
Safety Systems: Specialized power modules are often used for safety-related systems to ensure the integrity of the power supply to safety-rated components.
-
Critical Applications: Employed in redundant configurations (parallel operation) in applications requiring maximum uptime, such as power generation and continuous process control.
-
Global Deployments: Using wide-range input modules to simplify standardization across international plants with varying input power standards.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| 6GK5206-1BC10-2AA3 | SIEMENS | 6SE6400-0AP00-0AA1 | SIEMENS |
| 6ES7193-0CB20-0XA0 | SIEMENS | 6XV1840-3AH10 60m | SIEMENS |
| 6ES7323-1BH01-0AA0 | SIEMENS | QMX2.P33 | SIEMENS |
| 16137-175 | SIEMENS | PXC100-E96A | SIEMENS |
| 6GK443-1EX30-0XE1 | SIEMENS | 5SX2102-7 | SIEMENS |
| 6EP3331-6SB00-0AY0 | SIEMENS | 3ZX1012-ORTO2-1AA1 | SIEMENS |
| PXC50-E.D | SIEMENS | 6ES7151-1BA02-0AB0 | SIEMENS |
| 6AV2124-0QC24-1AX0 | SIEMENS | 6FX2001-6AA12-2AA5- 1 | SIEMENS |
| 6SL31201TE285AA3 | SIEMENS | 6ES7195-7HB00-0XA0 | SIEMENS |
| 6SL31622BM000AA0 | SIEMENS | 6SL34202TE150AA1 | SIEMENS |
| 6SE7972-0CB20-0XA0 | SIEMENS | 6SL3053-0AA00-3AA1 | SIEMENS |
| 3RX9307-1AA00 | SIEMENS | 6AV2124-0JC01-0AX0-ZA01+S00 | SIEMENS |
| 3RK1903-3AC00 | SIEMENS | QRA75.A17 | SIEMENS |
| 6GK5992-1AG00-8AA0 | SIEMENS | 3RT1054-1AT36 | SIEMENS |
| 6GK5980-3CB00-0AA1 | SIEMENS | 7MF4033-1DA10-1AC6-Z | SIEMENS |
| 6AG4141-0BA34-0EA0 | SIEMENS | 6AV8100-1CB00-0AA1 | SIEMENS |
| 5SU1324-7FA06 | SIEMENS | 3VL1705-1DA33-0AB1 | SIEMENS |
| 6SE7011-5EP50-Z | SIEMENS | 6SA8252-0BC83 | SIEMENS |
| 6DR2803-8P | SIEMENS | 6SN1124-1AB00-0HA1 | SIEMENS |
| FK-6DR4004-8J | SIEMENS | AK1703ACP | SIEMENS |
| 6SL3210 -1SE31-0UA0 | SIEMENS | 6SL3225-0BH27-5AA1 | SIEMENS |
| 6AV6645-0DE01-0AX1 | SIEMENS | 3TY7530-0A | SIEMENS |
| 6XV1870-8AN30 | SIEMENS | 3UG4512-1AR20 | SIEMENS |
| 3SE5132-0CJ82 | SIEMENS | 7SJ8021-5EB90-1FA0/DD | SIEMENS |
| 3RT1046-1BB44 + 3RH1921-1HA22 | SIEMENS | 3RH2911-1HA02 | SIEMENS |
| 3TF4522-0XM0 | SIEMENS | 6ES7288-1CR40-0AA0 | SIEMENS |
| 6AV2128-3UB06-0AX1 | SIEMENS | 6SE7090-0XX84-3EH0 | SIEMENS |
| 6SL3220-3YE30-0UF0 | SIEMENS | 6ES7135-0HF01-0XB0 | SIEMENS |
| 6SL3220-1YE34-0UF0 | SIEMENS | 6AG1134-4GB01-2AB0 | SIEMENS |
| TXM1.4D3R | SIEMENS | 6SC6508-4AA02 | SIEMENS |
| TXM1.6R | SIEMENS | 6SL3130-7TE25-5AA3 | SIEMENS |
| PXC4.E16 | SIEMENS | 8PQ9142-2AA04 | SIEMENS |
| QBM3120 | SIEMENS | 6ES7-214-1BD23-0XB8 | SIEMENS |
| TXS1-EF10 | SIEMENS | PXG80-N | SIEMENS |
| 6AG1231-4HD32-4XB0 | SIEMENS | 6GK51011BB002AA3 | SIEMENS |
| QVE1901 | SIEMENS | 6AG1137-6AA00-2BA0 | SIEMENS |
| QPA1004 | SIEMENS | 6EP1334-1AL11 | SIEMENS |
| GLB161.1E | SIEMENS | 6FX8002-2DC10-1EA0 | SIEMENS |



Phone:
Email:
WhatsApp:

