6EP1334-2AA01-0AB0 SIEMENS Filter Module SIEMENS

Brand: SIEMENS

Model number: 6EP1334-2AA01-0AB0

Colour:new                                    Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.5kg

Category: Brand:

Description

6EP1334-2AA01-0AB0 SIEMENS Filter Module

Product Dimensions:

Product Description

A Siemens Filter Module is an electrical or electronic component designed to improve the quality of power supply or signals within an industrial control system. Its primary purpose is to suppress or attenuate unwanted electrical noise, interference, and harmonic distortion.

These modules are essential for maintaining the reliable operation of sensitive electronic devices, such as PLCs, drives, and instrumentation, particularly in environments characterized by high electrical noise generated by devices like variable speed drives, motors, and switching power supplies. Filters can be broadly categorized as:

  1. Line Filters (EMC/RFI Filters): Installed on the power input lines to reduce conducted electromagnetic interference (EMI) and radio-frequency interference (RFI).

  2. Harmonic Filters: Used in power systems to mitigate harmonic distortion caused by non-linear loads, ensuring cleaner power quality.

  3. Signal Filters: Integrated into I/O circuitry to stabilize analog signals or suppress high-frequency noise in communication lines.

Product Parameters

The specifications of a Filter Module are determined by the electrical characteristics it is designed to manage:

Parameter  Description 
Rated Voltage/Current The maximum voltage and continuous current the filter is designed to handle (e.g., $480text{V AC}$, $10text{A}$).
Attenuation/Insertion Loss The measure of how effectively the filter reduces noise, measured in $text{dB}$ over a specific frequency range (e.g., $60text{dB}$ at $1text{MHz}$).
Filter Type The internal circuit design (e.g., single-stage, multi-stage, $text{L-C}$ filter, passive or active).
Frequency Range The range of noise frequencies the module is designed to suppress (e.g., $150text{kHz}$ to $30text{MHz}$).
Leakage Current The small amount of current that flows from the phases to the earth connection, which must be considered for safety regulations.
Protection Rating The Ingress Protection (IP) rating, indicating resistance to dust and moisture, especially for panel-mounted filters.
Harmonic Suppression For harmonic filters, the specified reduction in Total Harmonic Distortion ($text{THD}$) for voltage and current.

Product Advantages

  • Increased System Reliability: By mitigating electrical noise, filters prevent malfunctions, intermittent errors, and potential hardware damage in sensitive automation components.

  • EMC Compliance: Helps the overall system meet stringent electromagnetic compatibility (EMC) directives and regulatory standards, avoiding potential penalties and operational issues.

  • Improved Signal Quality: Ensures clean, stable power to sensitive instrumentation and clear, accurate transmission of analog and communication signals.

  • Extended Equipment Life: Reduces thermal stress and electrical disturbances on connected devices (like power supplies and drives), extending their service life.

  • Simplified Installation: Siemens filters are often designed for easy integration into control cabinets, matching the aesthetics and mounting features of other Siemens components.

Important Precautions

  • Proper Grounding: The filter’s performance is critically dependent on a low-impedance connection to the system’s protective earth (PE) ground. Ensure a short, thick connection cable or direct chassis mounting.

  • Sizing: The filter must be correctly rated for the maximum continuous current and voltage of the circuit it is protecting. Using an undersized filter can lead to overheating and failure.

  • Isolation: Power cables on the “unfiltered” side (source side) must be physically separated from the “filtered” side (load side) to prevent noise from coupling back into the clean circuit.

  • Leakage Current: Due to the internal capacitors, high-performance line filters often have significant leakage current to ground. Safety regulations must be reviewed to ensure the grounding system can handle this current without tripping safety devices.

  • Installation Environment: Install the filter module away from heat sources and ensure adequate ventilation, as it may dissipate some heat during operation.

Product Applications

Filter Modules are crucial in virtually any industrial setting where sensitive electronics operate alongside high-power devices:

  • Variable Speed Drive (VFD) Systems: Line filters are used to suppress the high-frequency switching noise generated by VFDs that can travel back onto the main power line.

  • Medical and Laboratory Equipment: Ensuring ultra-clean power is supplied to highly sensitive measurement devices.

  • Control Cabinets: Installed on the main power feed of a control cabinet to protect the PLC, power supplies, and I/O modules from external power disturbances.

  • Distributed Power Systems: Used to clean the power supply for remote I/O and communication hubs placed near heavy machinery.

  • Telecommunications: Filtering noise on data and communication lines in electrically noisy factory environments to maintain data integrity.

 

 

 

 

 

 

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

6GK5206-1BC10-2AA3  SIEMENS 6SE6400-0AP00-0AA1  SIEMENS
6ES7193-0CB20-0XA0  SIEMENS 6XV1840-3AH10 60m  SIEMENS
6ES7323-1BH01-0AA0  SIEMENS QMX2.P33  SIEMENS
16137-175  SIEMENS PXC100-E96A  SIEMENS
6GK443-1EX30-0XE1  SIEMENS 5SX2102-7  SIEMENS
6EP3331-6SB00-0AY0  SIEMENS 3ZX1012-ORTO2-1AA1  SIEMENS
 PXC50-E.D  SIEMENS 6ES7151-1BA02-0AB0  SIEMENS
6AV2124-0QC24-1AX0  SIEMENS 6FX2001-6AA12-2AA5- 1  SIEMENS
6SL31201TE285AA3  SIEMENS 6ES7195-7HB00-0XA0  SIEMENS
6SL31622BM000AA0  SIEMENS 6SL34202TE150AA1  SIEMENS
6SE7972-0CB20-0XA0  SIEMENS 6SL3053-0AA00-3AA1  SIEMENS
3RX9307-1AA00  SIEMENS 6AV2124-0JC01-0AX0-ZA01+S00  SIEMENS
3RK1903-3AC00  SIEMENS QRA75.A17  SIEMENS
6GK5992-1AG00-8AA0  SIEMENS 3RT1054-1AT36  SIEMENS
6GK5980-3CB00-0AA1  SIEMENS 7MF4033-1DA10-1AC6-Z  SIEMENS
6AG4141-0BA34-0EA0  SIEMENS 6AV8100-1CB00-0AA1  SIEMENS
5SU1324-7FA06  SIEMENS 3VL1705-1DA33-0AB1  SIEMENS
6SE7011-5EP50-Z  SIEMENS 6SA8252-0BC83  SIEMENS
6DR2803-8P  SIEMENS 6SN1124-1AB00-0HA1  SIEMENS
FK-6DR4004-8J  SIEMENS AK1703ACP  SIEMENS
6SL3210 -1SE31-0UA0  SIEMENS 6SL3225-0BH27-5AA1  SIEMENS
6AV6645-0DE01-0AX1  SIEMENS 3TY7530-0A  SIEMENS
6XV1870-8AN30  SIEMENS 3UG4512-1AR20  SIEMENS
3SE5132-0CJ82  SIEMENS 7SJ8021-5EB90-1FA0/DD  SIEMENS
3RT1046-1BB44 + 3RH1921-1HA22  SIEMENS 3RH2911-1HA02  SIEMENS
3TF4522-0XM0  SIEMENS 6ES7288-1CR40-0AA0  SIEMENS
6AV2128-3UB06-0AX1  SIEMENS 6SE7090-0XX84-3EH0  SIEMENS
6SL3220-3YE30-0UF0  SIEMENS 6ES7135-0HF01-0XB0  SIEMENS
6SL3220-1YE34-0UF0  SIEMENS 6AG1134-4GB01-2AB0  SIEMENS
TXM1.4D3R  SIEMENS 6SC6508-4AA02  SIEMENS
TXM1.6R  SIEMENS 6SL3130-7TE25-5AA3  SIEMENS
PXC4.E16  SIEMENS 8PQ9142-2AA04  SIEMENS
QBM3120  SIEMENS 6ES7-214-1BD23-0XB8  SIEMENS
TXS1-EF10  SIEMENS PXG80-N  SIEMENS
6AG1231-4HD32-4XB0  SIEMENS 6GK51011BB002AA3  SIEMENS
QVE1901  SIEMENS 6AG1137-6AA00-2BA0  SIEMENS
QPA1004  SIEMENS 6EP1334-1AL11  SIEMENS
GLB161.1E  SIEMENS 6FX8002-2DC10-1EA0  SIEMENS