6ES7340-1BH02-0AE0 SIEMENS Analog output module
Product Dimensions:
Product Description
A SIEMENS Analog Output (AO) Module is an interface device within a Programmable Controller (PLC) system dedicated to converting the digital setpoint values calculated by the Central Processing Unit (CPU) into continuous, variable electrical signals. This is achieved using high-resolution Digital-to-Analog Converters (DACs).
The primary function of the AO module is to command modulating field devices, enabling smooth and precise control over continuous physical quantities. These signals typically manifest as standard industrial current loops (e.g., $4-20text{ mA}$) or voltage outputs (e.g., $0-10text{ V}$).
The module includes advanced circuitry for electrical isolation, protection, and diagnostic feedback. It ensures that the digital setpoint is accurately and quickly translated into a stable, consistent analog signal that directly influences the operational parameter of the connected actuator, such as the speed of a motor or the position of a control valve.
Product Parameters
General technical parameters that define a Siemens Analog Output Module include:
| Parameter Category | General Specification |
| Channel Count | The number of independent output channels per module (e.g., 2, 4, 8 channels). |
| Output Signal Range | The supported standard current and voltage ranges (e.g., $0-20text{ mA}$, $4-20text{ mA}$, $0-10text{ V}$, $pm 10text{ V}$). |
| Resolution | The precision of the DAC, typically measured in bits (e.g., 12-bit, 16-bit), which determines the number of steps in the output signal. |
| Basic Error Limit (Accuracy) | The maximum permissible deviation of the actual output value from the theoretical value, usually expressed as a percentage of the full scale (e.g., $pm 0.1%$). |
| Isolation | Type of electrical isolation (e.g., channel-to-channel, channel-to-backplane) to prevent interference. |
| Permissible Load/Impedance | The maximum resistance the current output can drive or the minimum load the voltage output can supply. |
| Diagnostics | Integrated fault monitoring capabilities (e.g., open circuit/wire break detection, short circuit). |
| Settling Time | The time required for the output signal to reach a new commanded value within a specified tolerance, affecting control loop speed. |
Product Advantages
- High Precision and Fidelity: Utilizes high-resolution DACs to deliver extremely accurate and stable output signals, which is essential for maintaining tight control tolerances in sensitive processes.
- Integrated Diagnostics: Features include active monitoring for wire breaks in current loops and short circuits, allowing the PLC program to instantly detect faults and switch to a safe state, minimizing process disruption.
- Flexible Signal Configuration: Channels are often individually configurable for different signal types (current or voltage), providing flexibility to connect various field devices with a single module type.
- Galvanic Isolation: Offers strong electrical isolation to prevent ground loops and shield the sensitive electronics of the PLC from electrical disturbances originating in the field wiring.
- Fast Response: Designed with low settling times, enabling the module to react quickly to setpoint changes from the CPU, thereby improving the dynamic behavior of control loops.
Precautions
- Impedance/Load Matching: Ensure the resistance of the load device (e.g., a valve actuator) falls within the specified permissible load range of the module’s output type to prevent signal distortion or module damage.
- Signal Type Configuration: The software configuration (e.g., $0-10text{ V}$ or $4-20text{ mA}$) in the TIA Portal must exactly match the physical wiring and the required input of the field device.
- Wiring Integrity: Use high-quality, shielded, twisted-pair cabling for all analog signals to prevent external electromagnetic interference from inducing noise onto the control signal.
- Fail-Safe State: Program the controller to define a safe and predictable output value for the AO module (e.g., $0text{ mA}$ or a specific fail-safe value) in the event of a CPU stop, communication loss, or module failure.
- Scaling Consistency: Ensure that the digital value range used in the PLC program (e.g., $0$ to $27648$) is correctly scaled to correspond precisely to the physical output range and the full operational range of the final control element.
Product Applications
Analog Output Modules are vital for continuous control across numerous industrial sectors:
- Motor Speed Control: Setting the frequency or speed reference for Variable Frequency Drives (VFDs) to precisely control motor velocity in pumps, fans, or conveyors.
- Flow and Level Control: Modulating the opening of proportional valves or dampers to regulate flow rates or maintain liquid levels in tanks.
- Temperature Control: Providing the heat output command (e.g., $0-100%$) to industrial temperature controllers, ovens, or chillers.
- Robotics and Motion: Sending position, velocity, or torque setpoints to servo drives and advanced motion control systems.
- Process Regulation: Controlling reagent dosing, mixing ratios, or pressure setpoints in complex chemical and pharmaceutical processes.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| 6GK5206-1BC10-2AA3 | SIEMENS | 6SE6400-0AP00-0AA1 | SIEMENS |
| 6ES7193-0CB20-0XA0 | SIEMENS | 6XV1840-3AH10 60m | SIEMENS |
| 6ES7323-1BH01-0AA0 | SIEMENS | QMX2.P33 | SIEMENS |
| 16137-175 | SIEMENS | PXC100-E96A | SIEMENS |
| 6GK443-1EX30-0XE1 | SIEMENS | 5SX2102-7 | SIEMENS |
| 6EP3331-6SB00-0AY0 | SIEMENS | 3ZX1012-ORTO2-1AA1 | SIEMENS |
| PXC50-E.D | SIEMENS | 6ES7151-1BA02-0AB0 | SIEMENS |
| 6AV2124-0QC24-1AX0 | SIEMENS | 6FX2001-6AA12-2AA5- 1 | SIEMENS |
| 6SL31201TE285AA3 | SIEMENS | 6ES7195-7HB00-0XA0 | SIEMENS |
| 6SL31622BM000AA0 | SIEMENS | 6SL34202TE150AA1 | SIEMENS |
| 6SE7972-0CB20-0XA0 | SIEMENS | 6SL3053-0AA00-3AA1 | SIEMENS |
| 3RX9307-1AA00 | SIEMENS | 6AV2124-0JC01-0AX0-ZA01+S00 | SIEMENS |
| 3RK1903-3AC00 | SIEMENS | QRA75.A17 | SIEMENS |
| 6GK5992-1AG00-8AA0 | SIEMENS | 3RT1054-1AT36 | SIEMENS |
| 6GK5980-3CB00-0AA1 | SIEMENS | 7MF4033-1DA10-1AC6-Z | SIEMENS |
| 6AG4141-0BA34-0EA0 | SIEMENS | 6AV8100-1CB00-0AA1 | SIEMENS |
| 5SU1324-7FA06 | SIEMENS | 3VL1705-1DA33-0AB1 | SIEMENS |
| 6SE7011-5EP50-Z | SIEMENS | 6SA8252-0BC83 | SIEMENS |
| 6DR2803-8P | SIEMENS | 6SN1124-1AB00-0HA1 | SIEMENS |
| FK-6DR4004-8J | SIEMENS | AK1703ACP | SIEMENS |
| 6SL3210 -1SE31-0UA0 | SIEMENS | 6SL3225-0BH27-5AA1 | SIEMENS |
| 6AV6645-0DE01-0AX1 | SIEMENS | 3TY7530-0A | SIEMENS |
| 6XV1870-8AN30 | SIEMENS | 3UG4512-1AR20 | SIEMENS |
| 3SE5132-0CJ82 | SIEMENS | 7SJ8021-5EB90-1FA0/DD | SIEMENS |
| 3RT1046-1BB44 + 3RH1921-1HA22 | SIEMENS | 3RH2911-1HA02 | SIEMENS |
| 3TF4522-0XM0 | SIEMENS | 6ES7288-1CR40-0AA0 | SIEMENS |
| 6AV2128-3UB06-0AX1 | SIEMENS | 6SE7090-0XX84-3EH0 | SIEMENS |
| 6SL3220-3YE30-0UF0 | SIEMENS | 6ES7135-0HF01-0XB0 | SIEMENS |
| 6SL3220-1YE34-0UF0 | SIEMENS | 6AG1134-4GB01-2AB0 | SIEMENS |
| TXM1.4D3R | SIEMENS | 6SC6508-4AA02 | SIEMENS |
| TXM1.6R | SIEMENS | 6SL3130-7TE25-5AA3 | SIEMENS |
| PXC4.E16 | SIEMENS | 8PQ9142-2AA04 | SIEMENS |
| QBM3120 | SIEMENS | 6ES7-214-1BD23-0XB8 | SIEMENS |
| TXS1-EF10 | SIEMENS | PXG80-N | SIEMENS |
| 6AG1231-4HD32-4XB0 | SIEMENS | 6GK51011BB002AA3 | SIEMENS |
| QVE1901 | SIEMENS | 6AG1137-6AA00-2BA0 | SIEMENS |
| QPA1004 | SIEMENS | 6EP1334-1AL11 | SIEMENS |
| GLB161.1E | SIEMENS | 6FX8002-2DC10-1EA0 | SIEMENS |



Phone:
Email:
WhatsApp: