7XG2241-1AA00-0AA0 SIEMENS Digital input module
Product Dimensions:
Product Description
A Digital Input (DI) module is a plug-in component designed to detect the state of external devices, such as switches, sensors, or encoders. It monitors whether a voltage is present or absent at its input terminals—commonly referred to as “high” or “low” states. These modules perform signal conditioning, which includes voltage level conversion, filtering of contact bounce, and electrical isolation to protect the internal logic of the PLC from high-voltage surges or electrical noise on the factory floor.
Product Parameters
The technical specifications of digital input modules ensure they match the electrical characteristics of the field devices they monitor:
- Input Voltage: Standardized for industrial levels, most commonly 24V DC, though versions for 120V/230V AC also exist.
- Number of Channels: Available in high-density configurations, typically ranging from 8 to 32 channels per module.
- Input Delay: Adjustable filtering times (debounce) to prevent false triggering from mechanical switch vibrations.
- Input Characteristics: Defined by IEC 61131-2 (Type 1, 2, or 3), determining the current-sinking or current-sourcing behavior.
- Power Consumption: Low power draw from the backplane bus to ensure system efficiency.
- Status Indicators: Front-facing LEDs for each channel to indicate the logical state and diagnostic health.
Product Advantages
- Galvanic Isolation: Integrated optocouplers provide a physical break between the field circuit and the controller, preventing damage from ground loops or spikes.
- High Density: Compact designs allow for a large number of inputs in a small footprint, reducing the overall size of the control cabinet.
- Diagnostics: Advanced versions can detect wire breaks or short circuits at the individual channel level, reducing downtime.
- Hot-Swapping: Many modules support replacement while the system is under power, allowing for maintenance without stopping the entire process.
- Robustness: Engineered to operate in high-vibration and wide-temperature environments typical of heavy industry.
Important Considerations
- Sinking vs. Sourcing: It is critical to match the module’s wiring logic (NPN or PNP) with the sensors being used to ensure current flows correctly.
- Input Filtering: Setting the input delay too low may cause “noise” to be read as a signal, while setting it too high may cause the system to miss very fast pulses.
- Wiring Integrity: Proper shielding and separation from high-power cables are necessary to prevent electromagnetic induction from causing “ghost” signals.
- Voltage Drops: Long cable runs between the sensor and the module can result in voltage drops; ensure the voltage at the module terminal still meets the “High” threshold.
- Current Limits: Ensure the sensors used do not exceed the module’s maximum input current ratings to prevent overheating.
Product Applications
- Discrete Manufacturing: Monitoring the position of cylinders via limit switches or detecting the presence of parts on a conveyor using photoelectric sensors.
- Operator Interfacing: Capturing commands from pushbuttons, selector switches, and emergency stop signals on control panels.
- Process Monitoring: Receiving status signals from pressure switches, level float switches, or thermostats.
- Safety Systems: Integrating with light curtains and door interlocks to ensure machine guarding is active before operation.
- Sequence Control: Providing the feedback necessary for a PLC to move from one step of a programmed sequence to the next.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| 6GK5206-1BC10-2AA3 | SIEMENS | 6SE6400-0AP00-0AA1 | SIEMENS |
| 6ES7193-0CB20-0XA0 | SIEMENS | 6XV1840-3AH10 60m | SIEMENS |
| 6ES7323-1BH01-0AA0 | SIEMENS | QMX2.P33 | SIEMENS |
| 16137-175 | SIEMENS | PXC100-E96A | SIEMENS |
| 6GK443-1EX30-0XE1 | SIEMENS | 5SX2102-7 | SIEMENS |
| 6EP3331-6SB00-0AY0 | SIEMENS | 3ZX1012-ORTO2-1AA1 | SIEMENS |
| PXC50-E.D | SIEMENS | 6ES7151-1BA02-0AB0 | SIEMENS |
| 6AV2124-0QC24-1AX0 | SIEMENS | 6FX2001-6AA12-2AA5- 1 | SIEMENS |
| 6SL31201TE285AA3 | SIEMENS | 6ES7195-7HB00-0XA0 | SIEMENS |
| 6SL31622BM000AA0 | SIEMENS | 6SL34202TE150AA1 | SIEMENS |
| 6SE7972-0CB20-0XA0 | SIEMENS | 6SL3053-0AA00-3AA1 | SIEMENS |
| 3RX9307-1AA00 | SIEMENS | 6AV2124-0JC01-0AX0-ZA01+S00 | SIEMENS |
| 3RK1903-3AC00 | SIEMENS | QRA75.A17 | SIEMENS |
| 6GK5992-1AG00-8AA0 | SIEMENS | 3RT1054-1AT36 | SIEMENS |
| 6GK5980-3CB00-0AA1 | SIEMENS | 7MF4033-1DA10-1AC6-Z | SIEMENS |
| 6AG4141-0BA34-0EA0 | SIEMENS | 6AV8100-1CB00-0AA1 | SIEMENS |
| 5SU1324-7FA06 | SIEMENS | 3VL1705-1DA33-0AB1 | SIEMENS |
| 6SE7011-5EP50-Z | SIEMENS | 6SA8252-0BC83 | SIEMENS |
| 6DR2803-8P | SIEMENS | 6SN1124-1AB00-0HA1 | SIEMENS |
| FK-6DR4004-8J | SIEMENS | AK1703ACP | SIEMENS |
| 6SL3210 -1SE31-0UA0 | SIEMENS | 6SL3225-0BH27-5AA1 | SIEMENS |
| 6AV6645-0DE01-0AX1 | SIEMENS | 3TY7530-0A | SIEMENS |
| 6XV1870-8AN30 | SIEMENS | 3UG4512-1AR20 | SIEMENS |
| 3SE5132-0CJ82 | SIEMENS | 7SJ8021-5EB90-1FA0/DD | SIEMENS |
| 3RT1046-1BB44 + 3RH1921-1HA22 | SIEMENS | 3RH2911-1HA02 | SIEMENS |
| 3TF4522-0XM0 | SIEMENS | 6ES7288-1CR40-0AA0 | SIEMENS |
| 6AV2128-3UB06-0AX1 | SIEMENS | 6SE7090-0XX84-3EH0 | SIEMENS |
| 6SL3220-3YE30-0UF0 | SIEMENS | 6ES7135-0HF01-0XB0 | SIEMENS |
| 6SL3220-1YE34-0UF0 | SIEMENS | 6AG1134-4GB01-2AB0 | SIEMENS |
| TXM1.4D3R | SIEMENS | 6SC6508-4AA02 | SIEMENS |
| TXM1.6R | SIEMENS | 6SL3130-7TE25-5AA3 | SIEMENS |
| PXC4.E16 | SIEMENS | 8PQ9142-2AA04 | SIEMENS |
| QBM3120 | SIEMENS | 6ES7-214-1BD23-0XB8 | SIEMENS |
| TXS1-EF10 | SIEMENS | PXG80-N | SIEMENS |
| 6AG1231-4HD32-4XB0 | SIEMENS | 6GK51011BB002AA3 | SIEMENS |
| QVE1901 | SIEMENS | 6AG1137-6AA00-2BA0 | SIEMENS |
| QPA1004 | SIEMENS | 6EP1334-1AL11 | SIEMENS |
| GLB161.1E | SIEMENS | 6FX8002-2DC10-1EA0 | SIEMENS |