Description
ASZ 7.3 SIEMENS Input module
Product Dimensions:
Product Description
Input modules are specialized hardware components designed to capture signals from field devices such as switches, sensors, and transmitters. These modules are categorized into digital types, which detect binary states (on/off), and analog types, which measure continuous variables like pressure or temperature. Each module provides electrical isolation between the field environment and the internal system logic, protecting the sensitive central controller from electrical surges and noise common in industrial settings.
Product Parameters
The technical performance of an input module is defined by several critical specifications:
- Channel Density: The number of individual connection points available on a single module.
- Signal Voltage/Current: Standardized ranges for electrical inputs, such as 24V DC for digital signals or 4-20mA and 0-10V for analog signals.
- Resolution: For analog inputs, the precision of signal conversion, typically measured in bits.
- Filter Times: Configurable delay settings used to suppress contact bounce or electrical interference on input lines.
- Isolation: The dielectric strength provided to separate the field side from the backplane bus.
- Diagnostic Capabilities: The ability to detect and report wire breaks, short circuits, or power loss per channel.
Product Advantages
Siemens input modules offer superior reliability and high-speed signal acquisition. Their modular design allows for granular expansion, meaning users only need to install the exact number of inputs required for a specific task. They feature advanced diagnostics that significantly reduce downtime by identifying the exact location of a field fault. Furthermore, many modules support “hot-swapping,” allowing for replacement while the system is powered, and are engineered to maintain high accuracy even in environments with significant electromagnetic interference.
Precautions for Use
To maintain system integrity and accuracy, the following precautions should be observed:
- Wiring Separation: Signal cables should be routed away from high-voltage power lines to prevent inductive coupling and signal noise.
- Polarity Accuracy: Ensure correct polarity when connecting DC sensors to avoid damaging the module or the field device.
- Shielding and Grounding: For analog signals, proper use of shielded cables and single-point grounding is essential to prevent measurement drift.
- Channel Loading: Avoid exceeding the maximum rated voltage or current per channel to prevent overheating or permanent hardware failure.
Product Applications
Input modules are utilized across all automated industries to monitor the status of production processes. In manufacturing, they receive signals from limit switches and proximity sensors to track the position of parts. In process industries, they are used to monitor flow rates, levels, and temperatures via analog transmitters. They are also vital in safety applications, where they monitor emergency stop buttons and light curtains to ensure the protection of personnel and machinery.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| 6GK5206-1BC10-2AA3 | SIEMENS | 6SE6400-0AP00-0AA1 | SIEMENS |
| 6ES7193-0CB20-0XA0 | SIEMENS | 6XV1840-3AH10 60m | SIEMENS |
| 6ES7323-1BH01-0AA0 | SIEMENS | QMX2.P33 | SIEMENS |
| 16137-175 | SIEMENS | PXC100-E96A | SIEMENS |
| 6GK443-1EX30-0XE1 | SIEMENS | 5SX2102-7 | SIEMENS |
| 6EP3331-6SB00-0AY0 | SIEMENS | 3ZX1012-ORTO2-1AA1 | SIEMENS |
| PXC50-E.D | SIEMENS | 6ES7151-1BA02-0AB0 | SIEMENS |
| 6AV2124-0QC24-1AX0 | SIEMENS | 6FX2001-6AA12-2AA5- 1 | SIEMENS |
| 6SL31201TE285AA3 | SIEMENS | 6ES7195-7HB00-0XA0 | SIEMENS |
| 6SL31622BM000AA0 | SIEMENS | 6SL34202TE150AA1 | SIEMENS |
| 6SE7972-0CB20-0XA0 | SIEMENS | 6SL3053-0AA00-3AA1 | SIEMENS |
| 3RX9307-1AA00 | SIEMENS | 6AV2124-0JC01-0AX0-ZA01+S00 | SIEMENS |
| 3RK1903-3AC00 | SIEMENS | QRA75.A17 | SIEMENS |
| 6GK5992-1AG00-8AA0 | SIEMENS | 3RT1054-1AT36 | SIEMENS |
| 6GK5980-3CB00-0AA1 | SIEMENS | 7MF4033-1DA10-1AC6-Z | SIEMENS |
| 6AG4141-0BA34-0EA0 | SIEMENS | 6AV8100-1CB00-0AA1 | SIEMENS |
| 5SU1324-7FA06 | SIEMENS | 3VL1705-1DA33-0AB1 | SIEMENS |
| 6SE7011-5EP50-Z | SIEMENS | 6SA8252-0BC83 | SIEMENS |
| 6DR2803-8P | SIEMENS | 6SN1124-1AB00-0HA1 | SIEMENS |
| FK-6DR4004-8J | SIEMENS | AK1703ACP | SIEMENS |
| 6SL3210 -1SE31-0UA0 | SIEMENS | 6SL3225-0BH27-5AA1 | SIEMENS |
| 6AV6645-0DE01-0AX1 | SIEMENS | 3TY7530-0A | SIEMENS |
| 6XV1870-8AN30 | SIEMENS | 3UG4512-1AR20 | SIEMENS |
| 3SE5132-0CJ82 | SIEMENS | 7SJ8021-5EB90-1FA0/DD | SIEMENS |
| 3RT1046-1BB44 + 3RH1921-1HA22 | SIEMENS | 3RH2911-1HA02 | SIEMENS |
| 3TF4522-0XM0 | SIEMENS | 6ES7288-1CR40-0AA0 | SIEMENS |
| 6AV2128-3UB06-0AX1 | SIEMENS | 6SE7090-0XX84-3EH0 | SIEMENS |
| 6SL3220-3YE30-0UF0 | SIEMENS | 6ES7135-0HF01-0XB0 | SIEMENS |
| 6SL3220-1YE34-0UF0 | SIEMENS | 6AG1134-4GB01-2AB0 | SIEMENS |
| TXM1.4D3R | SIEMENS | 6SC6508-4AA02 | SIEMENS |
| TXM1.6R | SIEMENS | 6SL3130-7TE25-5AA3 | SIEMENS |
| PXC4.E16 | SIEMENS | 8PQ9142-2AA04 | SIEMENS |
| QBM3120 | SIEMENS | 6ES7-214-1BD23-0XB8 | SIEMENS |
| TXS1-EF10 | SIEMENS | PXG80-N | SIEMENS |
| 6AG1231-4HD32-4XB0 | SIEMENS | 6GK51011BB002AA3 | SIEMENS |
| QVE1901 | SIEMENS | 6AG1137-6AA00-2BA0 | SIEMENS |
| QPA1004 | SIEMENS | 6EP1334-1AL11 | SIEMENS |
| GLB161.1E | SIEMENS | 6FX8002-2DC10-1EA0 | SIEMENS |