Description
F2-04RTD FACTS Power module
Product Dimensions:
Product Description
The F2-04RTD is a 4-channel RTD input module that provides an interface between the PLC and various types of RTD temperature sensors. It converts resistance signals from the sensors into digital temperature data that the CPU can process. It is widely recognized for its high resolution and ability to handle multiple RTD types without the need for external signal conditioners.
Product Parameters
| Feature | Specification |
| Channels | 4 Isolated Channels |
| Input Type | Pt100, Pt1000, jPT100, Cu10, Ni120 |
| Resolution | 16-bit (0.1°C or 0.1°F) |
| Temperature Range | Varies by sensor (e.g., -200°C to 850°C for Pt100) |
| Accuracy | $\pm 0.1\%$ of full scale at 25°C |
| Update Rate | ~100ms per enabled channel |
| Input Impedance | $> 5 M\Omega$ |
| Power Consumption | Low wattage (typically powered via backplane) |
| Isolation | 1500VAC between field side and logic side |
Product Advantages
-
High Precision: The 16-bit resolution ensures extremely accurate temperature readings, which is critical for chemical and food processing.
-
Versatility: Supports multiple RTD types (Platinum, Nickel, Copper), allowing it to fit into various legacy and new installations.
-
Ease of Configuration: No hardware jumpers are required; the module is typically configured via the PLC programming software.
-
Robust Isolation: Protects the sensitive PLC backplane electronics from field-side electrical noise or surges.
-
Built-in Diagnostics: Features LED indicators for module status and individual channel errors (such as burnout or out-of-range signals).
Important Considerations
-
Wiring: Use shielded twisted-pair cable to minimize EMI (Electromagnetic Interference). Ensure the shield is grounded at the controller end only.
-
Sensor Distance: For long-distance wiring, use 3-wire or 4-wire RTDs to compensate for lead-wire resistance.
-
Environment: Ensure the ambient operating temperature stays within the specified range (usually 0°C to 60°C) to maintain accuracy.
-
Burnout Protection: The module can be configured to report a specific value (minimum or maximum) if a sensor wire breaks.
Product Applications
The F2-04RTD is ideal for any application requiring stable and accurate temperature measurement:
-
HVAC Systems: Monitoring ambient air and chilled water temperatures.
-
Food & Beverage: Precise control of pasteurization and baking temperatures.
-
Chemical Processing: Monitoring reactor vessel temperatures where high accuracy is safety-critical.
-
Plastic Injection Molding: Controlling heater band temperatures to ensure material consistency.
-
Pharmaceuticals: Cleanroom environmental monitoring and sterilization processes.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| DAC | 41072001 |
| DAIEI KOGYOSHA | AV-007 |
| Daihen | AMN-30C9 |
| Daihen | WGA-50E-V |
| Daihen | RMN-20E2-V |
| Daihen | RGA-50E-V |
| Daihen | RGA-10D-V |
| Daihen | MFM-15SA2V2 |
| Daihen | DGP-120A2-V |
| Daihen | DGP-120A2 |
| Daihen | AMN-50L-V |
| Daihen | AGA-50B2-V |
| Daihen | AGA-27C-V |
| DAIKIN | C-6RVN73HOV |
| DAIKIN | TM10AM-3R22-AT3N-10-217 |
| DAIKIN | AKS55K-F71 |
| DAIKIN | AKS35AK |
| DAIKIN | AKS55K-F71 |
| DAIKIN | AKS35AK |
| DAIKIN | AKS55K-F71 |
| DAIKIN | AKS35AK |
| dalsa | P3-12K40-01 |
| DAMETRIC | DCM-RM1 |
| DAMETRIC | DCA-02 |
| DANAHER MOTION | XMP-SYNQNET-PCI-RJ |
| DANFOSS | AK-SC255 |
| DANFOSS | FC301P15KT2E66H2 |
| DANFOSS | PT5C20SBR3DLF00A00C0 |
| DANFOSS | 175H1065 |
| DANMOTION | SC756A-001-01 |




Phone: