Description
KJ2002X1-CA1 EMERSON Input module
Product Dimensions:
Product Description
The KJ2002X1-CA1 acts as the central processing unit for a DeltaV node. It provides the logic execution for function blocks, manages the data flow from I/O modules, and communicates with the rest of the DeltaV network via redundant Ethernet ports. The M5 Controller is characterized by its significant processing speed and memory, making it a “mid-to-high” range controller capable of handling more demanding process applications than the M3 series.
Product Parameters
| Feature | Specification |
| Model Number | KJ2002X1-CA1 (VE3004) |
| Processor Type | High-speed RISC processor |
| LocalBus Power | +5 VDC at 1.4 A (Maximum) |
| Memory Capacity | High-capacity user memory for logic and tags |
| Communication Ports | Dual Redundant 10/100 Mbps Ethernet |
| Mounting | DeltaV 2-wide Power/Controller Carrier |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Hazardous Area Rating | ATEX II 3G, EEx nA IIC T4; Class I Div 2 |
| Conformal Coating | Standard (ISA-S71.04-1985 Class G3) |
Product Advantages
-
High Performance: Optimized for fast scan rates and complex control algorithms, ensuring stable control for high-speed loops.
-
Redundancy Support: Supports 1:1 redundancy. By using two controllers on a redundant carrier, the system ensures zero downtime; if the primary unit fails, the secondary unit takes over control seamlessly.
-
Automatic Configuration: Like other DeltaV controllers, it is “plug-and-play.” The system automatically recognizes the module when it is plugged into the carrier, simplifying commissioning.
-
Ruggedized Protection: Comes standard with G3 conformal coating, which protects the internal circuits against corrosion in harsh environments (like those with high sulfur or chlorine content).
-
Scalability: Allows users to build their system node-by-node, adding processing power only where it is needed in the plant.
Important Considerations & Precautions
-
Carrier Placement: This module must be installed on a DeltaV 2-wide Power/Controller carrier. It must be paired with a System Power Supply (such as the KJ1501X1 series).
-
Firmware Alignment: When replacing a controller or setting up a redundant pair, verify that the firmware on the controller matches the DeltaV software version of your workstation to avoid synchronization errors.
-
Heat Dissipation: Ensure that the cabinet has adequate ventilation. While the unit is rated to 60°C, consistent operation at the upper thermal limit can reduce the lifespan of the electronics.
-
Static Safety: Always use a grounded wrist strap when handling the controller. The high-speed RISC processor and memory chips are extremely sensitive to Electrostatic Discharge (ESD).
Product Applications
-
Chemical & Petrochemical: Ideal for controlling reactors, distillation columns, and blending units where precision and reliability are critical.
-
Oil & Gas: Used on offshore platforms and in refineries for process safety and production control.
-
Pharmaceuticals: Suitable for batch processing where high memory and fast data logging are required for regulatory compliance.
-
Power Generation: Managing boiler controls and auxiliary systems that require fast execution of logic to maintain grid stability.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| A6110 | EMERSON | KJ3006X1-BA1 | EMERSON |
| 211001BNA | EMERSON | KJ4001X1-CJ1 | EMERSON |
| VE4005S2B2 | EMERSON | VE4003S2B3 | EMERSON |
| RRE5009 | EMERSON | KJ3101X1-BB1 | EMERSON |
| 5X00070G01 | EMERSON | SLS1508 | EMERSON |
| A6110 | EMERSON | VE4001S2T2B1 | EMERSON |
| A6210 | EMERSON | VE4001S2T2B4 | EMERSON |
| A6312 | EMERSON | VE4002S1T2B1 | EMERSON |
| HART 475 | EMERSON | VE4002S1T2B5 | EMERSON |
| 211001BNA | EMERSON | VE4003S2B1 | EMERSON |
| EC3-X33 | EMERSON | VE4003S2B3 | EMERSON |
| 396572-04-9 | Emerson | 5X00070G01 | EMERSON |
| 12P2471X042 | EMERSON | 1B30035H01 | EMERSON |
| 12P3904X022 | EMERSON | 1C31132G01 | EMERSON |
| 12P3439X012 | EMERSON | 1C31129G03 | EMERSON |
| 00475-1130 | EMERSON | VE5009 | EMERSON |
| 1C31116G04 | EMERSON | 5X00119G01 | EMERSON |
| 5X00502G01 | EMERSON | 5X00121G01 | EMERSON |
| 5X00070G04 | EMERSON | 1C31129G03 | EMERSON |
| FLUXUS F721 | EMERSON | 1C31132G01 | EMERSON |
| 396657-01-0 | EMERSON | 5X00357G04 | EMERSON |
| 5X00062G01 | EMERSON | 5X00497G01 | EMERSON |
| 1X01046H01L | EMERSON | 5X00070G04 | EMERSON |
| FB3000 | EMERSON | 1C31116G04 | EMERSON |
| 1C31194G03 | EMERSON | KJ3243X1-BB2.1 + KJ3007X1-EA1.2 | Emerson |
| SS6501T01 | EMERSON | 33B7073X032 | EMERSON |
| 1X01046H01L | EMERSON | A6210 | EMERSON |
| SKC3400400 | EMERSON | A6630 | EMERSON |



Phone: