Description
MMI-NC-ENET-01 MagneMotion Controller module
Product Dimensions:
Product Description
The MMI-NC-ENET-01 is an industrial-grade controller that manages communications between the host controller (PLC/PC) and the individual motors on a MagneMotion track. It handles high-speed coordination, vehicle tracking, and system-wide synchronization over a standard Ethernet network. It essentially translates high-level commands into precise movement instructions for each independent carrier.
Product Parameters
| Feature | Specification |
| Catalog Number | MMI-NC-ENET-01 |
| Input Voltage | 6V DC to 36V DC |
| Power Dissipation | 40 W maximum |
| Network Interface | 10/100/1000BASE-TX (RJ45 Socket) |
| Digital I/O | 8 isolated input bits / 8 isolated output bits (DA-26) |
| Console Port | RS-232 (DE-9) for initial IP configuration |
| Node Support | Supports up to 16 nodes (configuration dependent) |
| Weight | Approx. 0.95 kg (2.06 lbs) |
| Operating Temp | 0°C to 50°C (32°F to 122°F) |
Product Advantages
-
Precision Coordination: Enables independent control of multiple carriers on a single track with sub-millimeter positioning.
-
Simplified Integration: Uses standard Ethernet protocols, making it easy to interface with Allen-Bradley Logix controllers or other third-party host systems.
-
Scalability: Allows for complex track layouts (switches, loops, and merges) by networking multiple node controllers together.
-
Built-in Diagnostics: Tracks system errors, motor health, and carrier locations in real-time, reducing downtime.
-
Compact Mounting: Includes kits for DIN rail, wall, or rack mounting, fitting easily into existing industrial cabinets.
Application Areas
-
Automotive Assembly: Moving small parts or battery cells through high-speed production lines.
-
Pharmaceutical Packaging: High-speed bottle filling, capping, and inspection where cleanliness and precision are critical.
-
Lab Automation: Moving samples between diagnostic stations without mechanical vibration.
-
Semiconductor: Cleanroom-compliant transport of wafers and sensitive electronics.
Precautions & Notes
-
Initial Setup: You must use the Console (RS-232) port to set the initial static IP address before the unit can be discovered on the Ethernet network.
-
Power Supply: Ensure the 24V DC power source is stable. Voltage drops below 6V or spikes above 36V can cause the controller to reset or suffer hardware damage.
-
Ethernet Ports: While some models have multiple ports, typically only Ethernet 1 is active for primary system control; check your specific firmware version for dual-port functionality.
-
Environmental Protection: The unit is rated for industrial use but should be kept in a non-condensing environment (max 95% humidity at 40°C).
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| DAC | 41072001 |
| DAIEI KOGYOSHA | AV-007 |
| Daihen | AMN-30C9 |
| Daihen | WGA-50E-V |
| Daihen | RMN-20E2-V |
| Daihen | RGA-50E-V |
| Daihen | RGA-10D-V |
| Daihen | MFM-15SA2V2 |
| Daihen | DGP-120A2-V |
| Daihen | DGP-120A2 |
| Daihen | AMN-50L-V |
| Daihen | AGA-50B2-V |
| Daihen | AGA-27C-V |
| DAIKIN | C-6RVN73HOV |
| DAIKIN | TM10AM-3R22-AT3N-10-217 |
| DAIKIN | AKS55K-F71 |
| DAIKIN | AKS35AK |
| DAIKIN | AKS55K-F71 |
| DAIKIN | AKS35AK |
| DAIKIN | AKS55K-F71 |
| DAIKIN | AKS35AK |
| dalsa | P3-12K40-01 |
| DAMETRIC | DCM-RM1 |
| DAMETRIC | DCA-02 |
| DANAHER MOTION | XMP-SYNQNET-PCI-RJ |
| DANFOSS | AK-SC255 |
| DANFOSS | FC301P15KT2E66H2 |
| DANFOSS | PT5C20SBR3DLF00A00C0 |
| DANFOSS | 175H1065 |
| DANMOTION | SC756A-001-01 |




Phone:
Email:
WhatsApp: