XP AHM250PS24T GeneralElectric Power module
Product Dimensions:
Product Description
The XP AHM250PS24T is a 250-Watt AC-DC power supply module featuring a single output of 24V DC. It is engineered to meet stringent global safety standards, including medical (EN/IEC60601-1) and industrial certifications. The “XP” designation often refers to the manufacturer XP Power (distributed or utilized within GE systems), known for high power density and versatile cooling options.
Product Parameters
| Feature | Specification |
| Input Voltage Range | 80 – 264 VAC (Universal Input) |
| Output Voltage | 24 VDC |
| Output Power | 250 Watts |
| Efficiency | Approximately 92% – 94% |
| Cooling | Convection cooled or Forced Air |
| Operating Temperature | -20°C to +70°C (Derating may apply above 50°C) |
| Safety Certifications | UL/EN/IEC 60601-1 (Medical), 62368-1 (ITE/Industrial) |
| Form Factor | Open Frame (Typical) |
| Isolation | 4000 VAC (Input to Output – 2 x MOPP) |
Key Advantages
-
High Efficiency: The high-efficiency rating reduces heat dissipation, allowing for a smaller physical footprint and improved long-term reliability.
-
Dual Certification: It is uniquely qualified for both medical and industrial use, meaning it features low leakage current and high isolation levels.
-
Compact Design: Designed to fit into tight spaces without sacrificing power output, making it ideal for portable medical equipment.
-
Quiet Operation: Because of its high efficiency, many models in this range can operate with minimal fan noise or via natural convection.
Critical Considerations & Precautions
-
Thermal Management: Ensure adequate airflow if the unit is being used at its maximum 250W rating. In enclosed spaces, the temperature must be monitored to prevent thermal shutdown.
-
Grounding: Proper earthing is essential to maintain safety standards and to minimize Electromagnetic Interference (EMI) in sensitive environments.
-
De-rating: Note that the output power may decrease at lower input voltages (below 90VAC) or at high ambient temperatures. Always consult the specific de-rating curve in the datasheet.
-
Handling: As an open-frame power supply, it contains high-voltage components. It should only be handled or installed by qualified personnel while the power is disconnected.
Product Applications
-
Medical Devices: Patient monitoring systems, diagnostic equipment, and medical imaging devices.
-
Industrial Automation: Control systems, robotics, and factory floor monitoring tools.
-
Telecommunications: Network routers, base stations, and data processing hardware.
-
Test and Measurement: Laboratory equipment and precision calibration tools.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| IC660BBA025 | General Electric | 469-P5-HI-A20-T-H | General Electric |
| CR104PSG92B11 | General Electric | Multilin PQMII-T20-C-A | General Electric |
| DS200UCPBG6A | General Electric | SGLA36AT0400 | General Electric |
| IC694BEM331CA | General Electric | UR 8FH | General Electric |
| IC697CMM711 | General Electric | IC697PWR711 | General Electric |
| 469-P5-HI-A20-E | General Electric | IC697CPX928 | General Electric |
| TB43400AF14 | General Electric | IC697BEM742 | General Electric |
| CR120B 022 02 | General Electric | IS200VRTDH1D | General Electric |
| FT-084 | General Electric | IC200ALG240 | General Electric |
| UR 7HH | General Electric | IC200CHS022 | General Electric |
| IS220PAICH2A | General Electric | IC200PWR001 | General Electric |
| IS200WROBH1A | General Electric | PRCZ11 | General Electric |
| IS200STAIH2ABB | General Electric | SFLA36A10250 | General Electric |
| IC660BBD024 | General Electric | IC200GBI001 | General Electric |
| IS200STAOH2AAA | General Electric | IC697RCM711 | General Electric |
| 469-P5-HI-A20-T-H | General Electric | IC693PWR331 | General Electric |
| UR 7HH | General Electric | IC693CPU374 | General Electric |
| IS220PAICH2A | General Electric | 55-154607G041 | General Electric |
| IS200WROBH1A | General Electric | 55-186556G0041 | General Electric |
| IS200STAIH2ABB | General Electric | UR 8FH | General Electric |
| IC660BBD024 | General Electric | KYPDACGP1 | General Electric |
| IS200STAOH2AAA | General Electric | UR 6UH | General Electric |
| 469-P5-HI-A20-T-H | General Electric | UR 6DH | General Electric |
| IC694ALG221 | General Electric | SKPA 36AT 1200 | General Electric |
| 8851-LC-MT | General Electric | UR RHH | General Electric |
| SFLA36A10250 | General Electric | IC697CPX928 | General Electric |
| CE693PWR330 | General Electric | IC697CMM742 | General Electric |
| 469-P5-HI-A20-T-H | General Electric | IC697BEM742 | General Electric |
| P9XPNNG | General Electric | IC697RCM711 | General Electric |
| P9XPNNG | General Electric | 369-HI-R-0-0-0-0-E | General Electric |




Phone:
Email:
WhatsApp: